McXtrace: Pump_probe_solvent Instrument at DTU

[ Identification | Description | Input parameters | Output parameters | Links ]

The Pump_probe_solvent Instrument

Design study of a pump and probe type instrument. The sample is an excitable molecule

Identification

  • Site: DTU
  • Author: Erik B Knudsen
  • Origin: DTU Fysik
  • Date: \today
  • Version: 0.2

Description

This is an example instrument for simulating time resolved scattering from
optically excitable, disordered molecules in solution, including scattering
signal from the solvent. By FSOLV it is possible to change the concentration of
solute.

This is to be considered a concept instrument model, i.e. it is _not_ a model of
an existing real instrument. A simple flat source emitting photons impinge on a chopper,
defining an X-ray pulse. Timing jitter in the chopper may be included through the JITTER
parameter which introduces a random uncertainty in the timing of the pulse.

The X-ray pulse is allowed to propagate to the sample which is excited by an instantaneous laser
pulse at t=0. The whole sample is assumed to be excited uniformly.
A Monte Carlo choice between interacting with solvent or solute is performed at the sample position.
The chopper is set such that the X-ray pulse front will arive at the sample at t=Dt. Thus,
setting Dt<-tau (chopper opening time) will simulate the "laser-off" setting.

The sampling of the scattered signal may be controlled by PSIMAX,PSIMIN and ETAMAX,ETAMIN
parameters. Please be aware the by restricting the azimuthal range it is not uncommon to underfill
the acceptance area of subsequent components. This is particularly the case for small psi.

Example: mxrun Pump_probe.instr Dt=2e-9 Detector: 1dpsd_I=2.78312e-26

Input parameters

Parameters in boldface are required; the others are optional.
Name Unit Description Default
excitation_prob 1 Fraction of the molecules in solution that are excited at t=0. 0.2
Dt 1 Time delay between laser pulse exciting the sample and the x-ray pulse. 100e-9
PSIMIN deg. Minimum scattering angle to be simulated. 0
PSIMAX deg. Maximum scattering angle to be simulated. 50
FSOLV =1 means only solvent, =0 only solute [ ] Volume fraction of solvent to solute. 0
JITTER s Jitter in chopper. 0
ETAMIN deg. Minimum azimuthal angle for scattered photons. -180
ETAMAX deg. Maximum azimuthal angle for scattered photons. 180
NOSOLVENT If nonzero - ignore scattering from solvent. 0
NOSOLUTE If nonzeor - ignore scattering from solute. 0