[ Identification | Description | Input parameters | Output parameters | Links ]

The TOF_monitor Component

Rectangular Time-of-flight monitor.

Identification

Description

A rectangular monitor which records instensity as a funtion of time of flight.
More precisely it bins photon rays according to the the state parameter time, t.

Input parameters

Parameters in boldface are required; the others are optional.
Name Unit Description Default
nt 1 Number of time bins 20
filename string Name of file in which to store the detector image 0
xmin m Lower x bound of detector opening -0.05
xmax m Upper x bound of detector opening 0.05
ymin m Lower y bound of detector opening -0.05
ymax m Upper y bound of detector opening 0.05
xwidth m Width of detector. Overrides xmin, xmax 0
yheight m Height of detector. Overrides ymin, ymax 0
tmin mu-s Lower time limit 0
tmax mu-s Upper time limit 0
dt mu-s Length of each time bin 1.0
restore_xray 1 If set, the monitor does not influence the xray state 0
nowritefile 1 If set, monitor will skip writing to disk 0

Output parameters

Name Unit Description Default
TOF_N  
TOF_p  
TOF_p2  
t_min  
t_max  
delta_t  

Links


[ Identification | Description | Input parameters | Output parameters | Links ]

Generated automatically by McDoc, Peter Willendrup <peter.willendrup@risoe.dk> / Mon Aug 16 15:54:47 2021