[ Identification | Description | Input parameters | Links ]

The ESRF_BM29 Instrument

ESRF BM29 SAXS beamline model

Identification

Description

Simple SAXS BM29 beamline model at ESRF:
https://www.esrf.fr/home/UsersAndScience/Experiments/MX/About_our_beamlines/bm29/beamline-specifications.html

Note that this model does not include much of the beamline optics, instead it emulates their effect
by setting relevant beam parameters from a model source.

Input parameters

Parameters in boldface are required; the others are optional.
NameUnitDescriptionDefault
DistanceFromSourceToFirstPinholemDistance to first pinhole from source.31.4
DistanceFromSourceToSecondPinholemDistance to second pinhole - used for focussing rays.42.5
DistanceFromSecondPinholeToSamplemCollimation length.0.1
DistanceFromSampleToDetectormSample-detector-distance.2.43
RadiusOfDetectormRadius of the circular detector.0.18
LambdaAAWavelength of the rays emitted from source.1.00
DLambdaRelative deviation of wavelength of the rays emitted from source.0.01

Links


[ Identification | Description | Input parameters | Links ]

Generated on 2023-12-19 19:37:45