[ Identification | Description | Input parameters | Links ]

The E_monitor Component

Energy-sensitive monitor.

Identification

Description

A square single monitor that measures the energy of the incoming x-rays.

Based on neutron component written by Kristian Nielsen and Kim Lefmann

Example: E_monitor(xmin=-0.1, xmax=0.1, ymin=-0.1, ymax=0.1,
Emin=1, Emax=50, nE=20, filename="Output.nrj")

Input parameters

Parameters in boldface are required; the others are optional.
NameUnitDescriptionDefault
nE1Number of energy channels20
filename1Name of file in which to store the detector image0
xminmLower x bound of detector opening-0.05
xmaxmUpper x bound of detector opening0.05
yminmLower y bound of detector opening-0.05
ymaxmUpper y bound of detector opening0.05
xwidthmWidth of detector. Overrides xmin,xmax.0
yheightmHeight of detector. Overrides ymin,ymax.0
EminkeVMinimum energy to detect
EmaxkeVMaximum energy to detect
restore_xray1If set, the monitor does not influence the xray state0
nowritefile1If set, monitor will skip writing to disk0
AT ( , , ) RELATIVE
ROTATED ( , , ) RELATIVE

Links


[ Identification | Description | Input parameters | Links ]

Generated on 2023-12-19 19:37:45