McXtrace: Monitor

[ Identification | Description | Input parameters | Links ]

The Monitor Component

Energy-sensitive monitor.

Identification

  • Site:
  • Author: Erik Knudsen
  • Origin: Risoe
  • Date: June 22, 2009

Description

A square single monitor that measures the intergated intensity of the incoming x-rays.

Based on neutron component written by Kristian Nielsen and Kim Lefmann

Example: Monitor(xmin=-0.1, xmax=0.1, ymin=-0.1, ymax=0.1)

Input parameters

Parameters in boldface are required; the others are optional.
NameUnitDescriptionDefault
xminLower x bound of detector opening (m)-0.05
xmaxUpper x bound of detector opening (m)0.05
yminLower y bound of detector opening (m)-0.05
ymaxUpper y bound of detector opening (m)0.05
xwidthWidth of detector. Overrides xmin,xmax. (m)0
yheightHeight of detector. Overrides ymin,ymax. (m)0
restore_xrayIf set, the monitor does not influence the xray state (1)0
AT ( , , ) RELATIVE
ROTATED ( , , ) RELATIVE