The MAXIV_DanMAX_pxrd1d Instrument

DanMAX Powder diffraction/Imaging beamline being designed at MAX IV.

Identification

  • Site: MAXIV
  • Author: Erik B Knudsen (erkn@fysik.dtu.dk)
  • Origin: DTU Physics
  • Date: Aug 2015

Description

Design study model of the DanMAX PowderX/Imaging beamline.
This early version uses a Gaussian approximation source, and a simple bandpass filter
as the multilayer.

Input parameters

Parameters in boldface are required; the others are optional.
NameUnitDescriptionDefault
E0keVThe central energy to sample from source model.35
DEkeVSpectral width (std. dev. if gaussian source) to sample from source model.0.05
undK Undulator K parameter, overrides E0.0
undDetuneeVFirst harmonic detuning in eV. When zero - max flux on axis. If set to approx. 4 eV one can gain ~20% of flux through the aperture.4
DCM_e0keVThe energy to tune the Si monochromator to. May be different from E0. If 0 the DCM is controlled by DCM_angle.35
DMM_e0keVThe energy to tune the ML monochromator to. May be different from E0. If 0 the DMM is controlled by DMM_angle.35
oh_premonohmPre-mono (white beam) slit height.1e-3
oh_premonowmPre-mono (white beam) slit width.1e-3
oh_endhmOH exit slit height.1e-3
oh_endwmOH exit slit width.1e-3
PXRDsampleap_hmPXRD clean-up aperture height.300e-6
PXRDsampleap_wmPXRD clean-up aperture width.300e-6
DMM_angledegGlancing angle of the ML.0
DCM_angledegGlacing angle of the Si-111 monochromator crystals.0
DCM If nonzero the high-resolution SI DCM is active.1
DMM If nonzero the multilayer mono is active.0
OH_2DCRL_N Number of 2D focus CRLs in the optics hutch transfocator. 0 means transfocator is inactive.11
EH_2DCRL_N0
D_EH_2DCRL0
PXRD_SIMPLE If zero - the full powder diffraction strip detector is active, else a single circular approximation is active.1
sample_radius100e-6
pxrd_strip_tth0degAngle offset of the PXRD 1d-strip detector from the optical axis.0
reflections"LaB6_660b_AVID2.hkl"
material"lab6.abs"
pack0.6
Vc71.830
density4.72
Absorb0
p_interact0.8
p_inc0.1
p_transmit0.1
debugMon If nonzero, all intermediate monitors appear for debugging purposes.1
beamStop If nonzero, a beamstop is in between sample and PXRD 1d-strip detector.0
SPLITS1410