The PSD_monitor_4PI Component

Spherical position-sensitive detector.

Identification

  • Site:
  • Author: Erik Knudsen
  • Origin: Risoe
  • Date: June 23rd, 2009

Description

Based on neutron component by Kim Lefmann and Kristian Nielsen
An (n times m) pixel spherical PSD monitor using a cylindrical projection.
Mostly for test and debugging purposes.

Example: PSD_monitor_4PI(radius=0.1,
nx=90, ny=90, filename="Output.psd")

Input parameters

Parameters in boldface are required; the others are optional.
NameUnitDescriptionDefault
radiusmRadius of detector1
restore_xray1If set, the monitor does not influence the xray state0
nx1Number of pixel columns90
ny1Number of pixel rows90
filenamestrName of file in which to store the detector image0
AT ( , , ) RELATIVE
ROTATED ( , , ) RELATIVE