5.3 Running the simulations
Once the simulation program has been generated by the McXtrace compiler mcxtrace and an
executable has been obtained with the C compiler, the simulation can be run in various
ways.
Simple McXtrace options
In this section, the most common simulation parameters are discussed. For a full list, please
consult Tables 5.1 and 5.2.
The simplest way is to run it directly from the command line or shell:
1 ./name.out
Note the leading “.”, which is needed if the current directory is not in the path searched
by the shell. When used in this way, the simulation will prompt for the values of
any instrument parameters such as angular settings, and then run the simulation.
Default instrument parameter values (see section 6.3), if any, will be indicated and
entered when hitting the Return key. This way of running McXtrace will only give
data for one instrument setting which is normally sufficient for e.g., time-of-flight,
SANS or powder instruments, but not for e.g. continuous-beam reflectometers or
triple-axis spectrometers where a scan over various instrument settings is required. Often
the simulation will be run using one of several available front-ends, as described in
the next section. These front-ends help manage output from the potentially many
detectors in the instruments, as well as running the simulation for each data point in a
scan.
The generated simulations accept a number of options and arguments. The full list can be
obtained using the --help option:
1 ./name.out --help
The values of instrument parameters may be specified as arguments using the syntax
name=val. For example
1 ./Template_1Slit_Diff.out SLITW=5e-6
The number of x-ray histories to simulate may be set using the --ncount or -n option, for
example --ncount=2e5. The initial seed for the random number generator is by default chosen
based on the current time so that it is different for each run. However, for debugging purposes
it is sometimes convenient to use the same seed for several runs, so that the same sequence of
random numbers is used each time. To achieve this, the random seed may be set using the
--seed or -s option.
By default, McXtrace simulations write their results into several data files in the
current directory, overwriting any previous files stored there. The --dir=dir or -ddir
option causes the files to be placed instead in a newly created directory dir (to
prevent overwriting previous results an error message is given if the directory already
exists).
The complete list of options and arguments accepted by McXtrace simulations appears in
Tables 5.1 and 5.2.
5.3.1 Choosing an output data file format
Data files contain header lines with information about the simulation from which they
originate. Use --format to select among the available formats (see below).
The format of the output files from McXtrace simulations is described in more detail in
section 5.5. It may be chosen either with --format=FORMAT for each simulation or globally by
setting the MCXTRACE_FORMAT environment variable. The available format list is
obtained using the name.out --help option. McXtrace can presently generate data in the
McXtrace/McCode text format or the NeXus format (see section 5.5.2).
It is also possible to read and write x-ray event lists using the MCPL_input/MCPL_output
components (see the Component Manual), which use the portable, compressed, multi-code
MCPL event format rather than any particular code’s native event format. This
is the recommended way to exchange x-ray events between McXtrace/McXtrace
and other Monte Carlo codes. The older, code-specific event-file components
(Virtual_input/Virtual_output, Virtual_mcnp_input/Virtual_mcnp_output,
Virtual_tripoli4_input/Virtual_tripoli4_output, Vitess_input/Vitess_output) still
exist for backward compatibility, but have moved to the obsolete component category (see
the Component Manual) and are no longer recommended for new instrument work in favour of
MCPL.
Additionally, adding the raw keyword to the FORMAT will produce raw \([N, p, p^2]\) data sets instead
of \([N, p, \sigma ]\) (see Section 4.2.1). The former representation is fully additive, and thus enables
to add results from separate simulations. Other acceptable format modifiers are
transpose to transpose data matrices and append to concatenate data to existing
files.
5.3.2 Basic import and plot of results
The previous example will result in a mccode.sim index file plus one data file per monitor
in the output directory. These are plain-text McXtrace/McCode format files (see
section 5.5) that can be read directly with NumPy (numpy.loadtxt) or any other
language capable of reading text tables, or, more conveniently, with the mxplot
front-end and its underlying data loader (mccodelib.mxplotloader), see section 5.4.6.
When using the HTML plotting back-end (mxplot-html), simulation results are rendered as
an interactive, self-contained web page (using D3.js) rather than being saved as static
images.
The full, up-to-date list of options accepted by mxrun and by the generated <instr>.out
executable is given in Tables 5.1 and 5.2 below. These tables are generated
automatically from the mxrun Python source (tools/Python/mxrun/mxrun.py)
by the script gen_mxrun_options_table.py in this directory, so that they cannot
silently go out of date; run mxrun --help for the same information at the command
line.
Table 5.1.: mxrun-specific options (compilation, scanning, optimisation, MPI/OpenACC).
| |
|
|
|
Option |
Description |
|
|
| |
| | |
|
-c --force-compile |
force rebuilding of instrument |
|
|
|
--cogen cogen |
Choice of code-generator (implies -c) |
|
|
|
-C --c-lint |
Use c-linter (e.g. cppcheck) to lint the generated
code. Configure linter via mccode_config.json.
Implies -c and -v, but also NO simulation will be
run. |
|
|
|
-I |
Append to McCode search path (implies -c) |
|
|
|
--D1 D1 |
Set extra -D args (implies -c) |
|
|
|
--D2 D2 |
Set extra -D args (implies -c) |
|
|
|
--D3 D3 |
Set extra -D args (implies -c) |
|
|
|
-p --param FILE |
Read parameters from file FILE |
|
|
|
-N --numpoints NP |
Set number of scan points |
|
|
|
--seeds SEEDS |
Set range of seeds to scan (each must be: SEED !=
0) |
|
|
|
-L --list |
Use a fixed list of points for linear scanning |
|
|
|
-M --multi |
Run a multi-dimensional scan |
|
|
|
--scan_split scan_split |
Scan by parallelising steps as individual cpu
threads. Initialise by number of wanted threads
(e.g. your number of cores). |
|
|
|
--autoplot |
Open plotter on generated dataset |
|
|
|
--invcanvas |
Forward request for inverted canvas to plotter |
|
|
|
--autoplotter |
Specify the plotter used with –autoplot |
|
|
|
--autodisplay |
Open mcdisplay with the monitor data of the
generated dataset |
|
|
|
--autodisplayer |
Specify the mcdisplay (webgl or webgl-classic)
used with –autodisplay, options may follow, e.g.
"mxdisplay-webgl --campath FILE" |
|
|
|
--embed |
Store copy of instrument file in output directory
(default: True) |
|
|
|
--mpi NB_CPU |
Spread simulation over NB_CPU machines using
MPI |
|
|
|
--openacc |
parallelize using openacc |
|
|
|
--funnel |
funneling simulation flow, e.g. for mixed CPU/GPU |
|
|
|
--machines machines |
Defines path of MPI machinefile to use in parallel
mode |
|
|
|
--optimise-file FILE |
Store scan results in FILE (defaults to:
”mccode.dat”) |
|
|
|
--no-cflags |
Disable optimising compiler flags for faster
compilation |
|
|
|
--no-main |
Do not generate a main(), e.g. for use with
mcstas2vitess.pl. Implies -c |
|
|
|
--verbose |
Enable verbose output |
|
|
|
--write-user-config |
Generate a user config file |
|
|
|
--edit-user-config |
Generate and edit user config file in EDITOR |
|
|
|
--override-config PATH |
Load config file from specific dir |
|
|
|
--optimize |
Optimize instrument variable parameters to
maximize monitors |
|
|
|
--optimize-maxiter optimize_maxiter |
Maximum number of optimization iterations to
perform. Default=1000 (default: 1000) |
|
|
|
--optimize-tol optimize_tol |
Tolerance
for optimization termination. When optimize-tol is
specified, the selected optimization algorithm sets
some relevant solver-specific tolerance(s) equal to
optimize-tol |
|
|
|
--optimize-method optimize_method |
Optimization solver in [...] (default: [...]) You
can use your custom method method(fun,
x0, args, **kwargs, **options). Please refer
to scipy documentation for proper use of it:
https://docs.scipy.org/doc/scipy/reference/generated/scipy.optimize.minimize.html?highlight=minimize |
|
|
|
--optimize-eval optimize_eval |
Optimization
expression to evaluate for each detector ”d”
structure. You may combine: ”d.intensity” The
detector intensity; ”d.error” The detector intensity
uncertainty; ”d.values” An array with [intensity,
error, counts]; ”d.X0 d.Y0” Center of signal (1st
moment); ”d.dX d.dY” Width of signal (2nd
moment). Default is ”d.intensity”. Examples are:
”d.intensity/d.dX” and ”d.intensity/d.dX/d.dY” |
|
|
|
--optimize-minimize |
Choose to minimize the monitors instead of
maximize |
|
|
|
--optimize-monitor optimize_monitor |
Name of a single monitor to optimize (default is to
use all) |
|
|
|
--showcfg ITEM |
Print selected cfg item and exit (paths are resolved
and absolute). Allowed values are particle. |
|
|
| |
| |
| |
| |
| |
Table 5.2.: Instrument/simulation options (also accepted directly by the generated
<instr>.out executable).
| |
|
|
|
Option |
Description |
|
|
| |
| | |
|
-s --seed SEED |
Set random seed (must be: SEED != 0) |
|
|
|
-n --ncount COUNT |
Set number of particles to simulate (default:
1000000) |
|
|
|
-t --trace trace |
Enable trace of particles through instrument
(default: 0) |
|
|
|
--no-trace notrace |
Disable trace of particles in instrument (combine
with -c) |
|
|
|
-y --yes |
Assume any default parameter value in instrument |
|
|
|
-d --dir DIR |
Put all data files in directory DIR. If unspecified
INSTRUMENT_TIMESTAMP is used |
|
|
|
--dirprefix dirprefix |
Put all data files in directory
PREFIX_TIMESTAMP |
|
|
|
--dirsuffix dirsuffix |
Put all data files in directory
INSTRUMENT_DIRSUFFIX |
|
|
|
-a --append |
Append data files to those already in directory DIR |
|
|
|
--format FORMAT |
Output data files using format FORMAT, usually
McCode or NeXus (format list obtained from
¡instr¿.out -h) (default: McCode) |
|
|
|
--bufsiz BUFSIZ |
Monitor_nD list/buffer-size (defaults to [...]) |
|
|
|
--vecsize VECSIZE |
vector length in OpenACC parallel scenarios |
|
|
|
--numgangs NUMGANGS |
number of ’gangs’ in OpenACC parallel scenarios |
|
|
|
--gpu_innerloop INNERLOOP |
Maximum particles in an OpenACC kernel run. (If
INNERLOOP is smaller than ncount we repeat) |
|
|
|
--no-output-files |
Do not write any data files |
|
|
|
-i --info |
Detailed instrument information |
|
|
|
--list-parameters |
Print the instrument parameters to standard out |
|
|
|
--meta-list |
Print all metadata defining component names |
|
|
|
--meta-defined |
Print metadata names for component, or indicate
if component:name exists |
|
|
|
--meta-type |
Print metadata type for component:name |
|
|
|
--meta-data |
Print metadata for component:name |
|
|
|
-g --gravitation --gravity |
Enable gravitation for all trajectories |
|
|
|
--IDF |
Flag to attempt inclusion of XML-based IDF
when –format=NeXus (format list obtained from
¡instr¿.out -h) |
|
|
| |
| |
| |
| |
| |
5.3.3 Interacting with a running simulation
Once the simulation has started, it is possible, under Unix, Linux and Mac OS X systems, to
interact with the on-going simulation. This feature is not available when using MPI
parallelization.
McXtrace attaches a signal handler to the simulation process. In order to send a signal to
the process, the process-id pid must be known. Users may look at their running processes with
the Unix ’ps’ command, or alternatively process managers like ’top’ and ’gtop’. If a file.out
simulation obtained from McXtrace is running, the process status command should output a
line resembling
1<user> 13277 7140 99 23:52 pts/2 00:00:13 file.out
2
where user is your Unix login. The pid is there ’13277’.
Once known, it is possible to send one of the signals listed in Table 5.3 using the ’kill’ unix
command (or the functionalities of your process manager), e.g.
1 kill -USR2 13277
2
This will result in a message showing status (here 33 % achieved), as well as the position in
the instrument of the current x-ray.
1# McXtrace: [pid 13277] Signal 12 detected SIGUSR2 (Save simulation)
2# Simulation: file (file.instr)
3# Breakpoint: MyDetector (Trace) 33.37 % ( 333654.0/ 1000000.0)
4# Date : Wed May 7 00:00:52 2003
5# McXtrace: Saving data and resume simulation (continue)
followed by the list of detector outputs (integrated counts and files). Finally, sending a
kill 13277 (which is equivalent to kill -TERM 13277) will end the simulation before the
initial ’ncount’ preset.
A typical usage example would be, for instance, to save data during a simulation, plot or
analyze it, and decide to interrupt the simulation earlier if the desired statistics has been
achieved. This may be done automatically using the Progress_bar component.
Whenever simulation data is generated before end (or the simulation is interrupted), the
’ratio’ field of the monitored data will provide the level of achievement of the computation (for
instance ’3.33e+05/1e+06’). Intensities are then usually to be scaled accordingly by the
user.
Additionally, any system error will result in similar messages, giving indication
about the occurrence of the error (component and section). Whenever possible, the
simulation will try to save the data before ending. Most errors appear when using a
newly written component, in the INITIALIZE, TRACE or FINALLY sections. Memory
errors usually show up when C pointers have not been allocated/unallocated before
usage, whereas mathematical errors are found when, for instance, dividing by zero.
|
|
| USR1 | Request information (status) |
| USR2, HUP
| Request information and performs an intermediate saving of
all monitors (status and save). This triggers the execution of
all SAVE sections (see chapter 6). |
| INT, TERM | Save and exit before end (status) |
|
|
| |
| Table 5.3.: | Signals supported by McXtrace simulations. |
5.3.4 Optimizing simulation speed
There are various ways to speed up simulations
-
Optimize the compilation of the instrument, as explained in section 5.2.4.
-
Execute the simulation in parallel on a computer cluster using MPI, or simply
across the cores of a single machine, as explained in section 5.6.
-
Divide simulation into parts using a file for saving or generating x-ray events. In
this way, a guide may be simulated only once, saving the x-ray events at the guide
exit as a file, which is being read quickly by the second simulation part. Use the
MCPL_output and MCPL_input components for this technique (see the Component
Manual).
-
Use source optimizers like the components Source_adapt or Source_Optimizer.
Such component may sometimes not be very efficient, when no x-ray importance
sampling can be achieved, or may even sometimes alter the simulation results. Be
careful and always check results with a (shorter) non-optimized computation.
-
Complex components usually take into account additional small effects in a
simulation, but are much longer to execute. Thus, simple components should be
preferred whenever possible, at least in the beginning of a simulation project.
-
The SPLIT keyword may artificially repeat events reaching specified positions in
the instrument. This is very efficient, but requires to cast random numbers in the
course of the remaining propagation (e.g. at samples, crystals, ...). See section 6.4.7
for details.
A general comment about optimization is that it should be used cautiously, checking that the
results are not significantly affected.
5.3.5 Optimizing instrument parameters
Often, the user may wish to optimize the parameters of a simulation, i.e. the best geometry of
a given component, for example the optimal curvature of a monochromator.
The choice of the optimization routine, of the simulation quality value to optimize,
the initial parameter guess and the simulation length all have a large influence on
the results. The user is advised to be cautious when interpreting the optimization
results.
Using iFit for optimization
One of the authors of McXtrace has developed a very flexible and general data analysis and
fitting package called iFit [EF14; Ifi] based on Matlab. Matlab itself is not required, as a
stand-alone distributable binary of iFit exists.
iFit contains wrapper functionality for compiling and running McXtrace simulations as
object functions, and allows to select many different optimizers, including swarms and other
non-gradient methods. Please see the iFit documentation for more information.
Our experience is that iFit together with McXtrace can be a more robust optimization
solution than the McXtrace built-in --optimize mode described next, in particular for
problems with many free parameters.
Using the built-in --optimize mode
The McXtrace package comes with a built-in optimization mode to find instrument parameters
that maximize (or minimize) the value of all, or some specified, monitors. As of McXtrace 3.x
this is implemented in mxrun using the scipy.optimize.minimize family of solvers [Sci],
replacing the earlier built-in Simplex/Nelder–Mead implementation. Available methods
include powell (the default), nelder-mead, cg, bfgs, newton-cg, l-bfgs-b, tnc, cobyla,
slsqp, trust-constr, dogleg, trust-ncg, trust-exact and trust-krylov; consult the
SciPy documentation for the properties of each. As with any non-linear optimizer,
results depend on the initial guess and the chosen method, and higher-dimensional
problems (many free parameters) are not guaranteed to converge to a meaningful, global
optimum.
When using mxrun (section 5.4.2), the optimization mode is set by using the --optimize
flag, together with instrument parameter ranges specified exactly as for a scan, e.g.
param=min,max. The solver is selected with --optimize-method=METHOD, the convergence
tolerance with --optimize-tol=TOL, and the maximum number of iterations with
--optimize-maxiter=N. By default all monitors are summed as the figure of merit;
a single monitor may be targeted instead with --optimize-monitor=NAME, and
--optimize-minimize inverts the sense of the search (minimize rather than maximize). For
full control over the optimized quantity (e.g. optimizing on peak width rather than
intensity), use --optimize-eval=EXPR with an expression combining the fields of a
detector structure d (d.intensity, d.error, d.values, d.X0/d.Y0, d.dX/d.dY), e.g.
--optimize-eval="d.intensity/d.dX". See Table 5.1 for the complete, up-to-date option
list.
Example:
1mxrun MyBeamline.instr --optimize --optimize-monitor=detector Slit_width=0.1,2
From mxgui (section 5.4.1), one should choose the ’Optimization’ execution mode (instead
of the Simulation or Trace mode). Then specify the instrument parameters to optimize by
indicating their variation range param=min,max (e.g. Lambda=1,4) just like parameter scans.
Finally, run the simulation. The optimum set of parameters is then printed at the end of the
simulation process. You may ask to maximize only a given monitor (instead of all) by selecting
its component name in the Run Dialog.
If you would like to maximize the flux at a given monitor, with some divergence constrains,
you should for instance simply add a divergence collimator before the monitor. Alternatively,
write a new component that produce the required ’figure-of-merit’.
The optimization search interval constrains the evolution of parameters. It should be chosen
carefully. In particular it is safer for it to indeed contain a high signal domain, and be
preferably symmetric with respect to that maximum.
Using custom optimization routines
For cases the built-in --optimize mode (or iFit) does not cover, the user may still write a
custom function/script or program that
-
inputs the simulation parameters, which are usually numerical values such as
a mirror curvature or a slit width, taken from an instrument in the examples
directory of the package.
-
builds a command line from these parameters.
-
executes that command, and waits until the end of the computation.
-
reads the relevant data from the monitors.
-
outputs a simulation quality measurement from this data, usually the integrated
counts or some peak width.
For instance, we could write a function for Python using scipy.optimize (or Matlab, if
preferred) in order to study the effect of a beamline parameter P on a given monitor’s
intensity:
1import subprocess
2from scipy.optimize import minimize_scalar
3import numpy as np
4
5def instr_value(P):
6 outdir = f"opt_{P:.3f}"
7 subprocess.run(["mxrun", "MyBeamline.instr", "-d", outdir, "-n", "1e6",
8 f"P={P}"], check=True)
9 # read back the relevant monitor’s plain-text McCode data file directly
10 data = np.loadtxt(f"{outdir}/detector.dat")
11 return -data[:, 1].sum() # negative intensity column sum: we minimize below
12
13result = minimize_scalar(instr_value, bounds=(0.1, 2.0), method="bounded")
will determine the best value of P in order to maximize the mean detector counts. This is
essentially what mxrun --optimize already automates for you (section 5.3.5.0); writing a
custom driver like this remains useful mainly when the figure of merit cannot be expressed as
a simple --optimize-eval expression, or when a non-scipy optimizer (e.g. a Matlab/iFit
swarm optimizer) is preferred.