The Detector_n McXtrace Component

12.9  The Detector_pn McXtrace Component

Version: McXtrace 1.2

Block of a attenuating material

Identification

  • Author: Maria Thomsen (mariath@fys.ku.dk)

  • Origin: NBI, KU

  • Date: Jan 24, 2011

Description

A scintillator detector model taking photoabsorption efficiency into account. As such it consitututes a more physical version of the PSD_monitor. Only direct absorption is taken into account.

Example: Detector_pn(restore_xray=restore_flag,filename=”detector_Si”, material_datafile=”Si.txt”, xwidth=1e-2, yheight=1e-2,zdepth=1e-5)

Input parameters

Parameters in boldface are required; the others are optional.

Name

Unit

Description

Default

material_datafile

str

File where the material parameters for the scintillator may be found. Format is similar to what may be found off the NIST website.

”Be.txt”

nx

m

Number of pixel columns.

90

ny

m

Number of pixel rows.

90

filename

str

Name of file in which to store the detector image.

””

restore_xray

If set, the monitor does not influence the xray state.

0

xwidth

m

Width of block.

1e-2

yheight

m

Height of block.

1e-2

zdepth

m

Thickness of block.

1e-6